Battery calculators / Runtime & backup
Understand your battery. Plan your power.
Battery calculator
Find your runtime, size a battery bank or work out a charge. Start with the runtime calculator below, or explore 49 focused tools with explained formulas and published sources.
Estimate battery runtime
Your result
Awaiting your inputsEnter your values and press Calculate. Your result will appear here.
Choose your calculation
All battery calculators
Different questions need different inputs. Find the right tool.
Runtime & backup
Battery Runtime CalculatorBattery Life by Amp DrawUPS Battery Runtime CalculatorBattery Backup Size CalculatorPeukert Battery Runtime CalculatorDuty Cycle Battery Life CalculatorEV and E-bike Battery Range CalculatorPower Bank Usable Capacity CalculatorStandby and Alarm Battery Load CalculatorEnergy & conversions
Battery Watt Hour CalculatorAh to mAh CalculatormAh to Ah CalculatorWh to kWh CalculatorkWh to Wh CalculatorWh to mWh CalculatormWh to Wh CalculatorWh to MJ CalculatormAh to Wh CalculatorWh to mAh CalculatorWh to Ah CalculatorWatts to Amp Hours CalculatorAmp Hours to Amps CalculatorAmps to Amp Hours CalculatorWatt Hours to Watts CalculatorWatts to Watt Hours CalculatorAmp Hours to Average Watts CalculatorBattery Voltage from Energy CalculatorCharging
Battery Charge Time CalculatorBattery Charger Size CalculatorEV Battery Charge Time CalculatorBattery Charging Cost CalculatorPacks & electrical
Battery Series and Parallel Pack CalculatorBattery C Rate CalculatorBattery Power and Current CalculatorBattery Internal Resistance CalculatorBattery Resistive Heat CalculatorBattery Cable Voltage Drop CalculatorHealth & measurement
Battery Capacity Test CalculatorBattery Health Percentage CalculatorBattery State of Charge CalculatorBattery Round Trip Efficiency CalculatorBattery Energy Density CalculatorEquivalent Full Battery Cycle CalculatorObserved Battery Degradation CalculatorReserve Capacity Delivered Ah CalculatorSolar & home storage
Solar Battery Size CalculatorSolar Battery Charge Time CalculatorHome Battery Load PlannerBattery Savings and Simple PaybackThe method
Formula and calculation steps
Runtime (h) = V × Ah × usable fraction × efficiency ÷ load W
Nominal energy is voltage multiplied by amp-hours. The selected usable fraction reserves part of that energy; efficiency applies once between the battery and load. Divide delivered watt-hours by constant load watts.
This energy-balance estimate does not model voltage sag, temperature, aging, Peukert losses or inverter cutoff. Enter measured capacity for an aged battery. A 100 Ah battery is not a 100 W power source.
Battery run time, backup time and battery life in hours
A battery runtime calculator and a battery backup time calculator answer the same energy-budget question: how long can the available battery energy support the entered load? Battery life here means hours of operation on one discharge, not years until replacement. For a laptop, camera, phone or portable DC supply, begin with rated Wh or multiply nominal volts by amp-hours, then account for the fraction actually available to the load.
A 12V battery run time calculator still needs capacity and load. For a 12V 7Ah battery, enter 12 V and 7 Ah; for a 50Ah or 200Ah battery, change the capacity field. Use the measured average power, including cycling and standby loads. Lithium-ion, LiFePO4 and lead-acid batteries can use the energy balance, but chemistry-specific current limits and usable capacity must come from the battery data.
Continue with: Battery Life by Amp Draw · Peukert Battery Runtime Calculator · UPS Battery Runtime Calculator · Battery Backup Size Calculator · Amp Hours to Average Watts Calculator
Worked example
A transparent starting point
A 12 V, 100 Ah battery at 80% usable capacity and 90% efficiency supplies 864 Wh: 8.64 hours at 100 W.
The values below are computed with the same formula as the calculator. They are examples, not manufacturer performance claims.
How one input changes the answer
| Continuous load (W) | Estimated runtime |
|---|---|
| 50 W | 17.28 hours |
| 100 W | 8.64 hours |
| 150 W | 5.76 hours |
All other inputs use the illustrative defaults in the form.
Battery run time, backup time and battery life in hours — calculated examples
Each row below is calculated from the stated case inputs. Inputs not changed in a row use the assumptions listed after the table.
| Case | Changed inputs | Result |
|---|---|---|
| 12V 7Ah at 10W | Nominal battery voltage: 12 V; Rated battery capacity: 7 Ah; Continuous load: 10 W | 6.048 hours |
| 12V 7Ah at 50W | Nominal battery voltage: 12 V; Rated battery capacity: 7 Ah; Continuous load: 50 W | 1.2096 hours |
| 12V 7Ah at 100W | Nominal battery voltage: 12 V; Rated battery capacity: 7 Ah; Continuous load: 100 W | 0.6048 hours |
| 12V 7Ah at 500W | Nominal battery voltage: 12 V; Rated battery capacity: 7 Ah; Continuous load: 500 W | 0.12096 hours |
| 12V 50Ah at 10W | Nominal battery voltage: 12 V; Rated battery capacity: 50 Ah; Continuous load: 10 W | 43.2 hours |
| 12V 50Ah at 50W | Nominal battery voltage: 12 V; Rated battery capacity: 50 Ah; Continuous load: 50 W | 8.64 hours |
| 12V 50Ah at 100W | Nominal battery voltage: 12 V; Rated battery capacity: 50 Ah; Continuous load: 100 W | 4.32 hours |
| 12V 50Ah at 500W | Nominal battery voltage: 12 V; Rated battery capacity: 50 Ah; Continuous load: 500 W | 0.864 hours |
| 12V 100Ah at 10W | Nominal battery voltage: 12 V; Rated battery capacity: 100 Ah; Continuous load: 10 W | 86.4 hours |
| 12V 100Ah at 50W | Nominal battery voltage: 12 V; Rated battery capacity: 100 Ah; Continuous load: 50 W | 17.28 hours |
| 12V 100Ah at 100W | Nominal battery voltage: 12 V; Rated battery capacity: 100 Ah; Continuous load: 100 W | 8.64 hours |
| 12V 100Ah at 500W | Nominal battery voltage: 12 V; Rated battery capacity: 100 Ah; Continuous load: 500 W | 1.728 hours |
| 12V 150Ah at 10W | Nominal battery voltage: 12 V; Rated battery capacity: 150 Ah; Continuous load: 10 W | 129.6 hours |
| 12V 150Ah at 50W | Nominal battery voltage: 12 V; Rated battery capacity: 150 Ah; Continuous load: 50 W | 25.92 hours |
| 12V 150Ah at 100W | Nominal battery voltage: 12 V; Rated battery capacity: 150 Ah; Continuous load: 100 W | 12.96 hours |
| 12V 150Ah at 500W | Nominal battery voltage: 12 V; Rated battery capacity: 150 Ah; Continuous load: 500 W | 2.592 hours |
| 12V 200Ah at 10W | Nominal battery voltage: 12 V; Rated battery capacity: 200 Ah; Continuous load: 10 W | 172.8 hours |
| 12V 200Ah at 50W | Nominal battery voltage: 12 V; Rated battery capacity: 200 Ah; Continuous load: 50 W | 34.56 hours |
| 12V 200Ah at 100W | Nominal battery voltage: 12 V; Rated battery capacity: 200 Ah; Continuous load: 100 W | 17.28 hours |
| 12V 200Ah at 500W | Nominal battery voltage: 12 V; Rated battery capacity: 200 Ah; Continuous load: 500 W | 3.456 hours |
| 24V 100Ah at 100W | Nominal battery voltage: 24 V; Rated battery capacity: 100 Ah; Continuous load: 100 W | 17.28 hours |
| 48V 100Ah at 100W | Nominal battery voltage: 48 V; Rated battery capacity: 100 Ah; Continuous load: 100 W | 34.56 hours |
Unchanged inputs: Nominal battery voltage = 12 V; Rated battery capacity = 100 Ah; Continuous load = 100 W; Usable capacity fraction = 80 %; Conversion efficiency = 90 %. Rows change only the listed inputs. Values are arithmetic examples, not manufacturer performance claims.
Common questions
Can this estimate a 12 V 7 Ah, 50 Ah or 200 Ah battery?
Yes. Change voltage and capacity rather than using a separate page for each battery size. Use the actual average load.
How should I use the result?
This energy-balance estimate does not model voltage sag, temperature, aging, Peukert losses or inverter cutoff. Enter measured capacity for an aged battery. A 100 Ah battery is not a 100 W power source.
How long will a 100Ah battery last at 100 watts?
At 12 V, 80% usable capacity and 90% conversion efficiency, the delivered energy is 864 Wh and estimated runtime is 8.64 hours. With different voltage or losses the answer changes; 100 Ah alone is insufficient.
How long will a 200Ah battery last?
At 12 V and the same 80% usable and 90% efficiency assumptions, a 200 Ah battery supplies 1,728 Wh to the load: 17.28 hours at 100 W or 3.456 hours at 500 W. These are energy estimates, not a manufacturer discharge curve.
Can I calculate battery runtime from Wh instead of Ah?
Yes. Runtime is usable delivered Wh divided by load watts. If the label only states Wh, divide Wh by nominal volts to enter the equivalent Ah in this form. Do not use charging voltage in that conversion.
How do I calculate battery life for a laptop, camera, phone or drone?
Use measured average operating watts and the battery energy. A drone has rapidly changing current, so a steady-load estimate is only a planning approximation. For a laptop, use present full-charge capacity rather than original design capacity when available.
Why is a lead acid battery runtime estimate too optimistic?
High current, low temperature, aging and early voltage cutoff can reduce delivered energy. The Peukert calculator models one rate effect under constant-current conditions; it does not remove the need for an actual discharge specification.
Is this a DigiKey, Omni, Enersys or Yuasa battery life calculator?
No. This independent energy-balance tool does not reproduce another provider software, chemistry model or proprietary performance data. Manufacturer curves remain necessary for a rated result.
What is different about lithium battery backup calculations?
Use the exact nominal voltage, present capacity and permitted usable fraction for the lithium-ion or LiFePO4 pack. The basic energy equation is the same, while the allowed current, cutoff behavior and charging profile can differ.
How do I calculate a 12V 7Ah battery run time?
At 80% usable capacity and 90% efficiency, a nominal 12 V 7 Ah battery supplies an estimated 60.48 Wh to a load. That is 6.048 hours at 10 W or 1.2096 hours at 50 W before unmodeled rate and cutoff effects.
Is an Enersys, Duracell, Yuasa or lithium battery formula universal?
No manufacturer name establishes a single discharge model. Enter the exact product ratings, and use its test conditions and performance data when the generic balance is not enough.
Related calculators
Sources and formula basis
Source addresses are shown as plain text. Algebraic rearrangements, example tables and user-selected loss factors are calculated on this site. A reference does not endorse every illustrative input.
- FAA — watt-hour rating: nominal volts × amp-hourshttps://www.faa.gov/hazmat/packsafe/airline-passengers-and-batteries
- Cadex Battery University BU-503 — power, energy and timehttps://www.batteryuniversity.com/article/bu-503-determining-power-deliver-by-the-ragone-plot
Source pages checked: November 19, 2026. Verify current product data and locally adopted requirements before design or installation.