Battery Calculatorby Voltage Drop Calculator

Battery calculators / Runtime & backup

Understand your battery. Plan your power.

Duty Cycle Battery Life Calculator

Estimate low-power device life from active and sleep currents, including CR2032 or sensor applications.

Your inputs

mAh
mA
mA
%
%

Defaults are illustrative. Enter your battery or equipment data. Efficiency and usable capacity inputs are percentages.

Your result

Awaiting your inputs

Enter your values and press Calculate. Your result will appear here.

Explained formula · Sources listed below · No sign-up

The method

Formula and calculation steps

Average mA = active mA × duty + sleep mA × (1 − duty); hours = usable mAh ÷ average mA

Weight each current by the fraction of time spent in that state. Capacity divided by the weighted average current gives an idealized operating duration.

Coin-cell pulse capability, self-discharge, temperature and cutoff can dominate real life. A capacity entry does not imply the cell can safely supply the active pulse.

CR2032, coin cell and IoT battery life calculation

An IoT device battery life calculator needs at least two operating states: active and sleep. Weight active current by the fraction of time the device is awake, then include sleep current for the rest. Small sleep currents can dominate a long deployment even when the active pulse looks much larger.

A CR2032 battery life calculator can perform this charge budget, but it cannot validate the cell pulse rating. Wireless transmit pulses, regulator quiescent current and voltage cutoff can shorten life. Manufacturer-branded sensor tools, including industrial transmitters, may include device-specific operating modes absent from this generic model.

Worked example

A transparent starting point

220 mAh, 10 mA active 1% of the time and 0.01 mA asleep at 80% usable gives about 1,601.46 hours.

The values below are computed with the same formula as the calculator. They are examples, not manufacturer performance claims.

How one input changes the answer

Time active (%)Ideal duty-cycle runtime
0.5 %2,935.78 hours
1 %1,601.456 hours
1.5 %1,101.032 hours

All other inputs use the illustrative defaults in the form.

CR2032, coin cell and IoT battery life calculation — calculated examples

Each row below is calculated from the stated case inputs. Inputs not changed in a row use the assumptions listed after the table.

CaseChanged inputsResult
0.1Time active: 0.1 %8,804.4022 hours
0.5Time active: 0.5 %2,935.77982 hours
1Time active: 1 %1,601.45587 hours
2Time active: 2 %838.89418 hours
5Time active: 5 %345.4367 hours
10Time active: 10 %174.43013 hours
20Time active: 20 %87.6494 hours
50Time active: 50 %35.16484 hours

Unchanged inputs: Cell capacity = 220 mAh; Active current = 10 mA; Sleep current = 0.01 mA; Time active = 1 %; Usable capacity fraction = 80 %. Rows change only the listed inputs. Values are arithmetic examples, not manufacturer performance claims.

Common questions

Can the result predict years of shelf life?

No. It ignores self-discharge and calendar aging; use the cell datasheet and a measured duty profile.

How should I use the result?

Coin-cell pulse capability, self-discharge, temperature and cutoff can dominate real life. A capacity entry does not imply the cell can safely supply the active pulse.

How do I estimate battery life for an IoT sensor?

Measure the complete device current in each state and enter the active duty percentage. Include sensor warm-up, radio retries and regulator current in the time-weighted average.

Can a coin cell deliver its capacity at any current?

No. The rated capacity is tied to test conditions. Pulse demands can cause voltage sag or premature shutdown even while charge remains.

Does the estimate include self-discharge or shelf life?

No. A tiny calculated current can imply a very long ideal duration, but calendar aging, leakage and self-discharge still limit actual service life.

How do I convert seconds awake to duty cycle?

Divide active seconds by the entire repeating period in seconds, then multiply by 100. One second awake every 100 seconds is a 1% active duty cycle.

Sources and formula basis

Source addresses are shown as plain text. Algebraic rearrangements, example tables and user-selected loss factors are calculated on this site. A reference does not endorse every illustrative input.

  1. Maccor — C-rate in battery testinghttps://www.maccor.com/battery-testing-knowledge-center/fundamentals/understanding-c-rate-in-battery-testing.html
  2. Cadex Battery University BU-904 — capacity testing and reserve capacityhttps://www.batteryuniversity.com/article/bu-904-how-to-measure-capacity

Source pages checked: November 19, 2026. Verify current product data and locally adopted requirements before design or installation.