Battery Calculatorby Voltage Drop Calculator

Battery calculators / Health & measurement

Understand your battery. Plan your power.

Reserve Capacity Delivered Ah Calculator

Calculate amp-hours actually delivered during a 25 A reserve-capacity test.

Your inputs

min

Defaults are illustrative. Enter your battery or equipment data. Efficiency and usable capacity inputs are percentages.

Your result

Awaiting your inputs

Enter your values and press Calculate. Your result will appear here.

Explained formula · Sources listed below · No sign-up

The method

Formula and calculation steps

Delivered charge at the RC test rate = 25 A × reserve minutes ÷ 60

Reserve capacity is a duration at a specified test current. Multiplying that duration by 25 A gives charge delivered at that test rate and cutoff.

This is not an accurate conversion to a 20-hour Ah rating and cannot convert CCA to Ah. Rate dependence and test conditions prevent a universal interchange.

Reserve capacity, CCA and amp-hour conversion limits

Battery reserve capacity describes minutes delivered under a specified reserve-capacity test. For the 25 A test rate, multiplying reserve minutes by 25/60 gives amp-hours actually delivered during that test. That quantity is not automatically a 20-hour capacity rating.

An Ah to CCA conversion chart or a battery CCA to Ah conversion calculator cannot provide one universal accurate relationship. Starting current capability and sustained charge capacity are different attributes, with different test conditions. Obtain separately rated values rather than treating a rough rule as a published conversion standard.

Worked example

A transparent starting point

120 reserve minutes at 25 A represents 50 Ah delivered during that test.

The values below are computed with the same formula as the calculator. They are examples, not manufacturer performance claims.

How one input changes the answer

Rated reserve capacity (min)Delivered charge at 25 A test rate
60 min25 Ah
120 min50 Ah
180 min75 Ah

All other inputs use the illustrative defaults in the form.

Reserve capacity, CCA and amp-hour conversion limits — calculated examples

Each row below is calculated from the stated case inputs. Inputs not changed in a row use the assumptions listed after the table.

CaseChanged inputsResult
30Rated reserve capacity: 30 min12.5 Ah
45Rated reserve capacity: 45 min18.75 Ah
60Rated reserve capacity: 60 min25 Ah
90Rated reserve capacity: 90 min37.5 Ah
120Rated reserve capacity: 120 min50 Ah
150Rated reserve capacity: 150 min62.5 Ah
180Rated reserve capacity: 180 min75 Ah
240Rated reserve capacity: 240 min100 Ah

Unchanged inputs: Rated reserve capacity = 120 min. Rows change only the listed inputs. Values are arithmetic examples, not manufacturer performance claims.

Common questions

Can I convert CCA to Ah?

No universal accurate conversion exists. Obtain a separate Ah rating or an appropriate capacity test.

How should I use the result?

This is not an accurate conversion to a 20-hour Ah rating and cannot convert CCA to Ah. Rate dependence and test conditions prevent a universal interchange.

Can I convert battery CCA to amp hours?

There is no universal accurate conversion. A high cranking-current rating does not by itself determine the Ah delivered over a long discharge.

Can I convert Ah to CCA with a fixed multiplier?

A fixed multiplier would hide differences in construction and test conditions. This site deliberately does not output a fabricated CCA value from Ah.

How do I calculate battery reserve capacity in Ah?

For the 25 A reserve test, delivered Ah = reserve minutes × 25 / 60. A 120-minute result corresponds to 50 Ah at that test rate.

Does 120 minutes of RC prove a 50Ah C20 rating?

No. It gives the charge delivered during the RC test. A separate C20 rating uses a different discharge condition.

Sources and formula basis

Source addresses are shown as plain text. Algebraic rearrangements, example tables and user-selected loss factors are calculated on this site. A reference does not endorse every illustrative input.

  1. Cadex Battery University BU-904 — capacity testing and reserve capacityhttps://www.batteryuniversity.com/article/bu-904-how-to-measure-capacity

Source pages checked: November 19, 2026. Verify current product data and locally adopted requirements before design or installation.