Battery calculators / Health & measurement
Understand your battery. Plan your power.
Battery State of Charge Calculator
Track a discharge-only state of charge estimate by coulomb counting.
Your inputs
Your result
Awaiting your inputsEnter your values and press Calculate. Your result will appear here.
The method
Formula and calculation steps
Estimated SoC % = starting SoC − 100 × discharged Ah ÷ actual full capacity Ah
Discharged amp-hours are average battery current multiplied by elapsed hours. Subtract that fraction of actual full-charge capacity from the starting estimate.
This model ignores self-discharge, drift and charge events. Use actual present capacity, not a degraded battery original rating. An out-of-range estimate is reported as inconsistent rather than silently clamped.
Battery charge percentage and state of charge estimation
Battery state of charge calculation by coulomb counting subtracts charge removed from a known starting estimate. A 100 Ah actual-capacity battery that starts full and delivers 40 Ah has an ideal remaining SoC of 60%. The capacity reference should reflect current usable capacity, not blindly use a degraded battery original rating.
Voltage-based battery percentage is a different estimation method. Battery chemistry, rest conditions and temperature affect the voltage-to-charge relationship. A single universal battery voltage percentage formula is especially unsuitable for a flat-discharge-curve chemistry.
Continue with: Battery Watt Hour Calculator · Battery Runtime Calculator
Worked example
A transparent starting point
A 100 Ah battery starting at 100%, discharged at 5 A for 8 hours, is estimated at 60% SoC.
The values below are computed with the same formula as the calculator. They are examples, not manufacturer performance claims.
How one input changes the answer
| Elapsed time (h) | Estimated remaining state of charge |
|---|---|
| 4 h | 80 % |
| 8 h | 60 % |
| 12 h | 40 % |
All other inputs use the illustrative defaults in the form.
Battery charge percentage and state of charge estimation — calculated examples
Each row below is calculated from the stated case inputs. Inputs not changed in a row use the assumptions listed after the table.
| Case | Changed inputs | Result |
|---|---|---|
| 0 | Elapsed time: 0 h | 100 % |
| 1 | Elapsed time: 1 h | 95 % |
| 2 | Elapsed time: 2 h | 90 % |
| 4 | Elapsed time: 4 h | 80 % |
| 8 | Elapsed time: 8 h | 60 % |
| 12 | Elapsed time: 12 h | 40 % |
| 16 | Elapsed time: 16 h | 20 % |
| 20 | Elapsed time: 20 h | 0 % |
Unchanged inputs: Rated battery capacity = 100 Ah; Starting state of charge = 100 %; Average discharge current = 5 A; Elapsed time = 8 h. Rows change only the listed inputs. Values are arithmetic examples, not manufacturer performance claims.
Common questions
Can I estimate SoC accurately from voltage alone?
Not with one universal equation. Chemistry, load, rest period and temperature affect the voltage-to-SoC relation.
How should I use the result?
This model ignores self-discharge, drift and charge events. Use actual present capacity, not a degraded battery original rating. An out-of-range estimate is reported as inconsistent rather than silently clamped.
How do I calculate battery charge percentage?
For discharge-only tracking, starting SoC minus 100 × discharged Ah / actual full-charge Ah gives an estimate. Enter average discharge current and elapsed time in this form.
Can I calculate SoC of a LiFePO4 battery from voltage?
Not accurately with a universal linear formula. Use an appropriate battery monitor and the manufacturer data; this page uses charge counting instead of an invented voltage table.
What is the difference between SoC and SoH?
SoC describes how full the present battery is. Capacity-based SoH compares its present maximum capacity with an original or design reference.
Does the state-of-charge estimate include charging?
This form tracks a discharge interval only. A complete monitor must also track charging current, charge efficiency and synchronization drift.
Related calculators
Sources and formula basis
Source addresses are shown as plain text. Algebraic rearrangements, example tables and user-selected loss factors are calculated on this site. A reference does not endorse every illustrative input.
- Cadex Battery University BU-903 — state-of-charge measurement methodshttps://www.batteryuniversity.com/article/bu-903-how-to-measure-state-of-charge
Source pages checked: November 19, 2026. Verify current product data and locally adopted requirements before design or installation.