The method
Formula and calculation steps
Loss % = (original − present) ÷ original × 100; average annual loss = loss % ÷ years
The annual figure is a simple average in percentage points of original capacity per year. It describes the supplied observations rather than predicting the next years.
Keep test conditions and capacity definitions consistent. Aging is not generally linear, and a capacity report can change after calibration or software updates.
EV battery degradation and observed capacity retention
An EV battery degradation calculator can summarize two comparable capacity measurements without pretending to know a future aging curve. Observed loss is the difference divided by the original reference. The average annual figure is a percentage-point loss relative to that reference.
A Tesla battery degradation calculation uses the same ratio only when original and present measurements describe comparable usable capacity. Displayed range alone may change with consumption estimates and is not necessarily a direct capacity test. Future or retired battery useful life needs a validated aging model.
Continue with: Battery Watt Hour Calculator · Battery Runtime Calculator
Worked example
A transparent starting point
60 kWh falling to 54 kWh over 3 years is a 10% observed loss, averaging 3.33 percentage points per year.
The values below are computed with the same formula as the calculator. They are examples, not manufacturer performance claims.
How one input changes the answer
| Present measured capacity (kWh) | Observed capacity loss |
|---|---|
| 27 kWh | 55 % |
| 54 kWh | 10 % |
| 81 kWh | -35 % |
All other inputs use the illustrative defaults in the form.
EV battery degradation and observed capacity retention — calculated examples
Each row below is calculated from the stated case inputs. Inputs not changed in a row use the assumptions listed after the table.
| Case | Changed inputs | Result |
|---|---|---|
| 60 | Present measured capacity: 60 kWh | 0 % |
| 59 | Present measured capacity: 59 kWh | 1.66667 % |
| 57 | Present measured capacity: 57 kWh | 5 % |
| 54 | Present measured capacity: 54 kWh | 10 % |
| 51 | Present measured capacity: 51 kWh | 15 % |
| 48 | Present measured capacity: 48 kWh | 20 % |
| 45 | Present measured capacity: 45 kWh | 25 % |
| 42 | Present measured capacity: 42 kWh | 30 % |
Unchanged inputs: Original measured capacity = 60 kWh; Present measured capacity = 54 kWh; Elapsed time = 3 years. Rows change only the listed inputs. Values are arithmetic examples, not manufacturer performance claims.
Common questions
Can I extrapolate this result to battery replacement?
No. This calculator reports history; future degradation depends on temperature, usage, chemistry and calendar aging.
How should I use the result?
Keep test conditions and capacity definitions consistent. Aging is not generally linear, and a capacity report can change after calibration or software updates.
How do I calculate battery degradation percentage?
Subtract present capacity from original measured capacity, divide by original capacity and multiply by 100.
How do I calculate annual battery degradation?
Divide observed percentage loss by elapsed years for a simple historical average. The result is percentage points of original capacity per year, not a compounded aging forecast.
Can I estimate useful battery life from two readings?
No reliable replacement date follows from two readings alone. Usage and calendar effects can be nonlinear, and measurements must first be comparable.
What if capacity appears to increase?
Check temperature, calibration, measurement boundary and software reporting. The calculator shows a negative observed loss rather than hiding the difference.
Related calculators
Sources and formula basis
Source addresses are shown as plain text. Algebraic rearrangements, example tables and user-selected loss factors are calculated on this site. A reference does not endorse every illustrative input.
- Cadex Battery University BU-904 — capacity testing and reserve capacityhttps://www.batteryuniversity.com/article/bu-904-how-to-measure-capacity
- NREL System Advisor Model — battery storage modeling and dispatchhttps://sam.nrel.gov/battery-storage/
Source pages checked: November 19, 2026. Verify current product data and locally adopted requirements before design or installation.