Battery Calculatorby Voltage Drop Calculator

Battery calculators / Energy & conversions

Understand your battery. Plan your power.

Battery Voltage from Energy Calculator

Recover a nominal voltage when the same battery label provides both energy and charge capacity.

Your inputs

Wh
mAh

Defaults are illustrative. Enter your battery or equipment data. Efficiency and usable capacity inputs are percentages.

Your result

Awaiting your inputs

Enter your values and press Calculate. Your result will appear here.

Explained formula · Sources listed below · No sign-up

The method

Formula and calculation steps

Nominal V = Wh × 1,000 ÷ mAh

Rearrange Wh = nominal V × Ah, converting mAh to Ah first. Both ratings must refer to the same cell or pack configuration.

mAh alone does not determine voltage. This calculation does not determine present terminal voltage, state of charge or the required charging voltage.

Why volts cannot be calculated from mAh alone

A battery voltage calculator based on a label can recover nominal volts when both Wh and charge capacity are stated for the same battery. It rearranges the energy relationship; it does not measure the voltage present at the terminals.

Searches for volts to mAh or amp hours to voltage need an additional energy value. The same mAh can exist at different cell or pack voltages. EMF and terminal voltage under load additionally depend on the battery state and electrical model; this label conversion does not solve those quantities.

Worked example

A transparent starting point

37 Wh × 1,000 ÷ 10,000 mAh = 3.7 V nominal.

The values below are computed with the same formula as the calculator. They are examples, not manufacturer performance claims.

How one input changes the answer

Rated energy (Wh)Inferred nominal voltage
18.5 Wh1.85 V
37 Wh3.7 V
55.5 Wh5.55 V

All other inputs use the illustrative defaults in the form.

Why volts cannot be calculated from mAh alone — calculated examples

Each row below is calculated from the stated case inputs. Inputs not changed in a row use the assumptions listed after the table.

CaseChanged inputsResult
37Wh and 10000mAhRated energy: 37 Wh; Rated charge capacity: 10,000 mAh3.7 V
53Wh and 10000mAhRated energy: 53 Wh; Rated charge capacity: 10,000 mAh5.3 V
100Wh and 10000mAhRated energy: 100 Wh; Rated charge capacity: 10,000 mAh10 V
24Wh and 2000mAhRated energy: 24 Wh; Rated charge capacity: 2,000 mAh12 V
48Wh and 2000mAhRated energy: 48 Wh; Rated charge capacity: 2,000 mAh24 V
120Wh and 10000mAhRated energy: 120 Wh; Rated charge capacity: 10,000 mAh12 V
240Wh and 10000mAhRated energy: 240 Wh; Rated charge capacity: 10,000 mAh24 V
480Wh and 10000mAhRated energy: 480 Wh; Rated charge capacity: 10,000 mAh48 V

Unchanged inputs: Rated energy = 37 Wh; Rated charge capacity = 10,000 mAh. Rows change only the listed inputs. Values are arithmetic examples, not manufacturer performance claims.

Common questions

Can I use USB output mAh with cell-level Wh?

No. Mixing different measurement boundaries gives a misleading voltage. Use matching label ratings.

How should I use the result?

mAh alone does not determine voltage. This calculation does not determine present terminal voltage, state of charge or the required charging voltage.

How do I calculate battery voltage from Wh and mAh?

Divide Wh×1,000 by mAh. Matching 37 Wh and 10,000 mAh ratings imply 3.7 V nominally.

Can I convert volts to mAh?

Only when matching energy is known: mAh = Wh×1,000/V. Voltage by itself cannot establish battery charge capacity.

How is terminal voltage of a battery calculated?

A simple source model uses EMF minus current times internal resistance under discharge, but actual terminal voltage depends on conditions. This tool only recovers nominal voltage from label energy and capacity.

Does the result give a safe charging voltage?

No. Nominal voltage is not a charger setpoint. Obtain the correct chemistry, series count and charging profile from the manufacturer.

Sources and formula basis

Source addresses are shown as plain text. Algebraic rearrangements, example tables and user-selected loss factors are calculated on this site. A reference does not endorse every illustrative input.

  1. FAA — watt-hour rating: nominal volts × amp-hourshttps://www.faa.gov/hazmat/packsafe/airline-passengers-and-batteries
  2. NIST — SI units and prefixeshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-chapter-4-two-classes-si-units-and-si-prefixes
  3. Victron Wiring Unlimited §2 — electrical theory, cable resistance and voltage drophttps://www.victronenergy.com/media/pg/The_Wiring_Unlimited_book/en/theory.html
  4. Cadex Battery University BU-902 — internal resistance measurementhttps://www.batteryuniversity.com/article/bu-902-how-to-measure-internal-resistance

Source pages checked: November 19, 2026. Verify current product data and locally adopted requirements before design or installation.