Battery Calculatorby Voltage Drop Calculator

Battery calculators / Energy & conversions

Understand your battery. Plan your power.

Amps to Amp Hours Calculator

Calculate amps to amp hours with all required electrical inputs.

Your inputs

A
h

Defaults are illustrative. Enter your battery or equipment data. Efficiency and usable capacity inputs are percentages.

Your result

Awaiting your inputs

Enter your values and press Calculate. Your result will appear here.

Explained formula · Sources listed below · No sign-up

The method

Formula and calculation steps

Ah = A × hours

Use the measured average current when the load cycles.

This is an algebraic energy or charge calculation. It does not establish a battery discharge rating or charger compatibility.

Calculating amp hours from amps and operating hours

Amp-hours measure accumulated electrical charge. For steady current, Ah = A × hours. For a load that changes, compute each interval separately and add the charge: a 2 A interval for 3 hours plus 1 A for 4 hours consumes 10 Ah.

A battery amp hour calculation based on measured current can help establish daily demand, but it is not automatically the battery Ah nameplate rating. Include inactive periods, actual duty cycle and capacity reserve when turning a consumption measurement into installed storage.

Worked example

A transparent starting point

5 A for 8 hours = 40 Ah.

The values below are computed with the same formula as the calculator. They are examples, not manufacturer performance claims.

How one input changes the answer

Average current (A)Charge consumed
2.5 A20 Ah
5 A40 Ah
7.5 A60 Ah

All other inputs use the illustrative defaults in the form.

Calculating amp hours from amps and operating hours — calculated examples

Each row below is calculated from the stated case inputs. Inputs not changed in a row use the assumptions listed after the table.

CaseChanged inputsResult
0.05A for 8hAverage current: 0.05 A; Operating duration: 8 h0.4 Ah
0.05A for 24hAverage current: 0.05 A; Operating duration: 24 h1.2 Ah
1A for 8hAverage current: 1 A; Operating duration: 8 h8 Ah
1A for 24hAverage current: 1 A; Operating duration: 24 h24 Ah
5A for 8hAverage current: 5 A; Operating duration: 8 h40 Ah
5A for 24hAverage current: 5 A; Operating duration: 24 h120 Ah
10A for 8hAverage current: 10 A; Operating duration: 8 h80 Ah
10A for 24hAverage current: 10 A; Operating duration: 24 h240 Ah

Unchanged inputs: Average current = 5 A; Operating duration = 8 h. Rows change only the listed inputs. Values are arithmetic examples, not manufacturer performance claims.

Common questions

Why do I need the extra input?

Use the measured average current when the load cycles.

How should I use the result?

This is an algebraic energy or charge calculation. It does not establish a battery discharge rating or charger compatibility.

How are amp hours calculated?

Multiply the average current in amperes by elapsed hours. For a variable load, sum the A×h contribution of each interval or integrate logged current.

How many Ah does 5 amps use in a day?

A constant 5 A over 24 hours consumes 120 Ah. A cycling load with 5 A only while on consumes less and requires a duty fraction.

Can I calculate amp hours from volts alone?

No. Voltage does not specify charge capacity. You need current and time, or energy and voltage.

How do I calculate Ah on Excel?

For current in cell B2 and hours in C2, the formula is =B2*C2. Keep the units consistent and sum interval results for variable current.

Sources and formula basis

Source addresses are shown as plain text. Algebraic rearrangements, example tables and user-selected loss factors are calculated on this site. A reference does not endorse every illustrative input.

  1. FAA — watt-hour rating: nominal volts × amp-hourshttps://www.faa.gov/hazmat/packsafe/airline-passengers-and-batteries
  2. NIST — SI units and prefixeshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-chapter-4-two-classes-si-units-and-si-prefixes
  3. Cadex Battery University BU-503 — power, energy and timehttps://www.batteryuniversity.com/article/bu-503-determining-power-deliver-by-the-ragone-plot

Source pages checked: November 19, 2026. Verify current product data and locally adopted requirements before design or installation.