Battery calculators / Packs & electrical
Understand your battery. Plan your power.
Battery Resistive Heat Calculator
Estimate only the ohmic heating associated with a supplied battery resistance.
Your inputs
Your result
Awaiting your inputsEnter your values and press Calculate. Your result will appear here.
The method
Formula and calculation steps
Resistive heat W = I² × R; heat Wh = I² × R × hours
Convert milliohms to ohms, multiply by current squared, then multiply by duration for resistive heat energy.
This is not total electrochemical heat or a thermal-runaway model. It excludes reversible entropy heat, cooling and temperature-dependent resistance; no cell temperature is predicted.
Battery pack and UPS resistive heat dissipation
A battery heat dissipation calculation based on I²R estimates only irreversible ohmic heating at a specified current and resistance. The square relationship means doubling the current produces four times this resistive power when resistance remains unchanged.
For a UPS battery heat dissipation calculation, battery resistance heating is only one part of system heat. Inverter losses, charger electronics and electrochemical heat are separate. A brake resistor calculation also needs its own energy duty and component ratings; it cannot be inferred from battery I²R alone.
Continue with: Battery Watt Hour Calculator · Battery Runtime Calculator
Worked example
A transparent starting point
20 A through 10 mΩ gives 4 W of resistive heat, or 4 Wh in one hour.
The values below are computed with the same formula as the calculator. They are examples, not manufacturer performance claims.
How one input changes the answer
| Continuous battery current (A) | Resistive heat only |
|---|---|
| 10 A | 1 W |
| 20 A | 4 W |
| 30 A | 9 W |
All other inputs use the illustrative defaults in the form.
Battery pack and UPS resistive heat dissipation — calculated examples
Each row below is calculated from the stated case inputs. Inputs not changed in a row use the assumptions listed after the table.
| Case | Changed inputs | Result |
|---|---|---|
| 5A through 5mΩ | Continuous battery current: 5 A; Effective DC resistance: 5 mΩ | 0.125 W |
| 5A through 10mΩ | Continuous battery current: 5 A; Effective DC resistance: 10 mΩ | 0.25 W |
| 10A through 5mΩ | Continuous battery current: 10 A; Effective DC resistance: 5 mΩ | 0.5 W |
| 10A through 10mΩ | Continuous battery current: 10 A; Effective DC resistance: 10 mΩ | 1 W |
| 20A through 5mΩ | Continuous battery current: 20 A; Effective DC resistance: 5 mΩ | 2 W |
| 20A through 10mΩ | Continuous battery current: 20 A; Effective DC resistance: 10 mΩ | 4 W |
| 50A through 5mΩ | Continuous battery current: 50 A; Effective DC resistance: 5 mΩ | 12.5 W |
| 50A through 10mΩ | Continuous battery current: 50 A; Effective DC resistance: 10 mΩ | 25 W |
Unchanged inputs: Continuous battery current = 20 A; Effective DC resistance = 10 mΩ; Operating duration = 1 h. Rows change only the listed inputs. Values are arithmetic examples, not manufacturer performance claims.
Common questions
Does 4 W tell me the battery temperature?
No. Temperature requires thermal mass, ambient conditions and cooling characteristics.
How should I use the result?
This is not total electrochemical heat or a thermal-runaway model. It excludes reversible entropy heat, cooling and temperature-dependent resistance; no cell temperature is predicted.
What is the battery heat dissipation formula?
Ohmic power is I²R with current in A and resistance in ohms. Convert milliohms to ohms before multiplying.
How do I calculate heat energy over time?
Multiply resistive watts by operating hours for Wh. At 20 A through 10 milliohms, power is 4 W and one hour produces 4 Wh of resistive heat.
Can I size battery cooling from this result?
Not by itself. Total heat sources, ambient conditions, thermal mass, enclosure and cooling paths are needed to estimate temperature and cooling capacity.
Does this calculate thermal runaway?
No. Thermal runaway and abuse behavior require chemistry-specific testing and models, outside a constant-resistance heat estimate.
Related calculators
Sources and formula basis
Source addresses are shown as plain text. Algebraic rearrangements, example tables and user-selected loss factors are calculated on this site. A reference does not endorse every illustrative input.
- Victron Wiring Unlimited §2 — electrical theory, cable resistance and voltage drophttps://www.victronenergy.com/media/pg/The_Wiring_Unlimited_book/en/theory.html
- Cadex Battery University BU-902 — internal resistance measurementhttps://www.batteryuniversity.com/article/bu-902-how-to-measure-internal-resistance
Source pages checked: November 19, 2026. Verify current product data and locally adopted requirements before design or installation.