Battery Internal Resistance Calculator
Estimate battery DC resistance from a controlled change in load.
Your inputs
Your result
Awaiting your inputsEnter your values and press Calculate. Your result will appear here.
The method
Formula and calculation steps
DC step resistance = (V before − V loaded) ÷ change in current
The voltage response divided by the current change gives the effective DC resistance at the selected sampling time. Leads and contacts are included unless a four-wire method removes them.
Do not short a battery to take this measurement. Results depend on state of charge, temperature and sampling duration and differ from AC impedance measurements.
Internal resistance formula from a battery load step
For a controlled DC discharge step, effective internal resistance is the drop in voltage divided by the increase in current. The load must change in a defined manner and voltage samples must refer to a consistent point in the response. A larger drop at the same current change corresponds to a larger effective resistance.
The battery internal resistance formula for Excel is =(V_before-V_loaded)/delta_I in ohms, or that expression times 1,000 in milliohms. Cable and contact resistance affect a two-wire reading. AC impedance, a short DC pulse and a long DC test do not necessarily measure the same battery response.
Continue with: Battery Watt Hour Calculator · Battery Runtime Calculator
Worked example
A transparent starting point
(12.8 − 12.6) V ÷ 20 A = 0.010 Ω = 10 mΩ.
The values below are computed with the same formula as the calculator. They are examples, not manufacturer performance claims.
How one input changes the answer
| Change in load current (A) | Effective DC resistance |
|---|---|
| 10 A | 20 mΩ |
| 20 A | 10 mΩ |
| 30 A | 6.666667 mΩ |
All other inputs use the illustrative defaults in the form.
Internal resistance formula from a battery load step — calculated examples
Each row below is calculated from the stated case inputs. Inputs not changed in a row use the assumptions listed after the table.
| Case | Changed inputs | Result |
|---|---|---|
| 5A step, 0.2V drop | Change in load current: 5 A; Voltage under load: 12.6 V | 40 mΩ |
| 5A step, 0.1V drop | Change in load current: 5 A; Voltage under load: 12.7 V | 20 mΩ |
| 10A step, 0.2V drop | Change in load current: 10 A; Voltage under load: 12.6 V | 20 mΩ |
| 10A step, 0.1V drop | Change in load current: 10 A; Voltage under load: 12.7 V | 10 mΩ |
| 20A step, 0.2V drop | Change in load current: 20 A; Voltage under load: 12.6 V | 10 mΩ |
| 20A step, 0.1V drop | Change in load current: 20 A; Voltage under load: 12.7 V | 5 mΩ |
| 40A step, 0.2V drop | Change in load current: 40 A; Voltage under load: 12.6 V | 5 mΩ |
| 40A step, 0.1V drop | Change in load current: 40 A; Voltage under load: 12.7 V | 2.5 mΩ |
Unchanged inputs: Voltage immediately before load step = 12.8 V; Voltage under load = 12.6 V; Change in load current = 20 A. Rows change only the listed inputs. Values are arithmetic examples, not manufacturer performance claims.
Common questions
Can resistance alone determine remaining capacity?
No. Compare like-for-like measurements and perform an appropriate capacity test for capacity-based health.
How should I use the result?
Do not short a battery to take this measurement. Results depend on state of charge, temperature and sampling duration and differ from AC impedance measurements.
How do I calculate internal resistance of a battery?
Subtract loaded voltage from the voltage before the step, then divide by the current increase. For a 0.2 V drop at 20 A, resistance is 0.01 ohm or 10 milliohms.
Can I estimate battery short circuit current with V/R?
V/R is a simple source-resistance model, but the measured resistance and real battery behavior are not sufficient to establish a rated fault current or protection interrupt requirement. This page does not provide a fault-current design calculation.
Does increased resistance prove the exact capacity loss?
No. Resistance and charge capacity are different measurements. Compare controlled test conditions and use an appropriate capacity test for capacity retention.
Should I short the terminals to measure resistance?
No. Use an appropriate controlled test method and equipment; do not create a short circuit to obtain these inputs.
Related calculators
Sources and formula basis
Source addresses are shown as plain text. Algebraic rearrangements, example tables and user-selected loss factors are calculated on this site. A reference does not endorse every illustrative input.
- Cadex Battery University BU-902 — internal resistance measurementhttps://www.batteryuniversity.com/article/bu-902-how-to-measure-internal-resistance
- Victron Wiring Unlimited §2 — electrical theory, cable resistance and voltage drophttps://www.victronenergy.com/media/pg/The_Wiring_Unlimited_book/en/theory.html
Source pages checked: November 19, 2026. Verify current product data and locally adopted requirements before design or installation.