Battery calculators / Solar & home storage
Understand your battery. Plan your power.
Solar Battery Size Calculator
Size battery storage for a daily energy demand and a specified number of days without recharge.
Your inputs
Your result
Awaiting your inputsEnter your values and press Calculate. Your result will appear here.
The method
Formula and calculation steps
Nominal kWh = daily load kWh × autonomy days ÷ (usable fraction × discharge efficiency)
Multiply daily energy by autonomy. Divide by usable capacity fraction and discharge-path efficiency to obtain nominal battery energy, then convert to Ah at the bank voltage.
This is a storage-only balance. It does not predict local sunshine, seasonal yield, panel area or charge-controller size. Daily energy does not establish inverter surge capacity.
Solar battery sizing for off-grid and home storage
An off grid battery size calculator starts with daily load energy and days of autonomy without charging. Divide that energy requirement by the selected usable fraction and discharge efficiency to estimate nominal storage. Ah then depends on the battery bank voltage.
A solar panel and battery calculation needs two related balances: enough storage for the intended no-sun period, and enough PV energy to run loads and restore the bank when sunlight returns. This page sizes storage only. Regional searches for the UK, Australia, Canada, India, New Zealand or South Africa do not change the arithmetic, but local weather, tariffs and installation requirements change the inputs.
Continue with: Home Battery Load Planner · Solar Battery Charge Time Calculator · Battery Savings and Simple Payback
Worked example
A transparent starting point
5 kWh/day for 2 days, 80% usable and 90% discharge efficiency needs 13.89 kWh nominal storage.
The values below are computed with the same formula as the calculator. They are examples, not manufacturer performance claims.
How one input changes the answer
| Autonomy without charging (days) | Required nominal storage |
|---|---|
| 1 days | 6.944444 kWh |
| 2 days | 13.88889 kWh |
| 3 days | 20.83333 kWh |
All other inputs use the illustrative defaults in the form.
Solar battery sizing for off-grid and home storage — calculated examples
Each row below is calculated from the stated case inputs. Inputs not changed in a row use the assumptions listed after the table.
| Case | Changed inputs | Result |
|---|---|---|
| 2kWh/day, 1 days | Daily load energy: 2 kWh/day; Autonomy without charging: 1 days | 2.77778 kWh |
| 2kWh/day, 2 days | Daily load energy: 2 kWh/day; Autonomy without charging: 2 days | 5.55556 kWh |
| 5kWh/day, 1 days | Daily load energy: 5 kWh/day; Autonomy without charging: 1 days | 6.94444 kWh |
| 5kWh/day, 2 days | Daily load energy: 5 kWh/day; Autonomy without charging: 2 days | 13.88889 kWh |
| 10kWh/day, 1 days | Daily load energy: 10 kWh/day; Autonomy without charging: 1 days | 13.88889 kWh |
| 10kWh/day, 2 days | Daily load energy: 10 kWh/day; Autonomy without charging: 2 days | 27.77778 kWh |
| 20kWh/day, 1 days | Daily load energy: 20 kWh/day; Autonomy without charging: 1 days | 27.77778 kWh |
| 20kWh/day, 2 days | Daily load energy: 20 kWh/day; Autonomy without charging: 2 days | 55.55556 kWh |
Unchanged inputs: Daily load energy = 5 kWh/day; Autonomy without charging = 2 days; Nominal battery voltage = 12 V; Usable capacity fraction = 80 %; Conversion efficiency = 90 %. Rows change only the listed inputs. Values are arithmetic examples, not manufacturer performance claims.
Common questions
Is this a location-specific solar simulation?
No. Use measured demand and a local hourly solar model for a full system design.
How should I use the result?
This is a storage-only balance. It does not predict local sunshine, seasonal yield, panel area or charge-controller size. Daily energy does not establish inverter surge capacity.
What size solar battery do I need?
Use measured daily load kWh and the number of days to cover without charging, then allow for usable capacity and discharge losses. A household bill total is not necessarily the critical backup energy.
How do I calculate battery size for a solar system?
Nominal kWh = daily load kWh × autonomy days / (usable fraction × efficiency). Convert to Ah with the intended bank voltage.
Can I size solar panels and batteries with one result?
No. Battery autonomy and PV charging resource are separate constraints. Use the solar charge-time tool for an explicit PV input check, then a location-specific system model for a full design.
Is this a solar battery calculator for Australia or the UK?
It can use locally measured energy demand and user-supplied inputs, but does not load a regional tariff, weather dataset or subsidy. The form is not a country-specific installation design.
Does it choose the best battery for solar storage?
No. It estimates capacity. Compare approved equipment ratings, usable energy, power capability, warranties and installation suitability separately.
Related calculators
Sources and formula basis
Source addresses are shown as plain text. Algebraic rearrangements, example tables and user-selected loss factors are calculated on this site. A reference does not endorse every illustrative input.
- FAA — watt-hour rating: nominal volts × amp-hourshttps://www.faa.gov/hazmat/packsafe/airline-passengers-and-batteries
- NREL System Advisor Model — battery storage modeling and dispatchhttps://sam.nrel.gov/battery-storage/
Source pages checked: November 19, 2026. Verify current product data and locally adopted requirements before design or installation.