Battery Calculatorby Voltage Drop Calculator

Battery calculators / Energy & conversions

Understand your battery. Plan your power.

Watts to Amp Hours Calculator

Calculate watts to amp hours with all required electrical inputs.

Your inputs

W
h
V
%

Defaults are illustrative. Enter your battery or equipment data. Efficiency and usable capacity inputs are percentages.

Your result

Awaiting your inputs

Enter your values and press Calculate. Your result will appear here.

Explained formula · Sources listed below · No sign-up

The method

Formula and calculation steps

Ah = W × hours ÷ (V × efficiency)

This computes consumed Ah. Divide by an additional usable fraction to size a larger battery.

This is an algebraic energy or charge calculation. It does not establish a battery discharge rating or charger compatibility.

Watts to amp hours for 12V battery loads

A watts to amp hours calculator needs operating time, nominal voltage and a conversion efficiency when watts are measured after a converter. First compute load energy as watts times hours, then divide by efficiency and voltage to get battery charge consumed.

For calculating amp hours needed, distinguish discharged charge from installed capacity. The form returns consumed Ah. A battery reserved to 80% usable capacity must be larger than that charge requirement: divide consumed Ah by 0.8. The battery-backup-size calculator includes this extra step and a separate margin.

Worked example

A transparent starting point

100 W for 8 hours at 12 V and 90% efficiency requires 74.07 Ah discharged.

The values below are computed with the same formula as the calculator. They are examples, not manufacturer performance claims.

How one input changes the answer

Continuous load (W)Charge consumed from battery
50 W37.03704 Ah
100 W74.07407 Ah
150 W111.1111 Ah

All other inputs use the illustrative defaults in the form.

Watts to amp hours for 12V battery loads — calculated examples

Each row below is calculated from the stated case inputs. Inputs not changed in a row use the assumptions listed after the table.

CaseChanged inputsResult
100W for 1hContinuous load: 100 W; Operating duration: 1 h9.25926 Ah
100W for 8hContinuous load: 100 W; Operating duration: 8 h74.07407 Ah
300W for 1hContinuous load: 300 W; Operating duration: 1 h27.77778 Ah
300W for 8hContinuous load: 300 W; Operating duration: 8 h222.22222 Ah
500W for 1hContinuous load: 500 W; Operating duration: 1 h46.2963 Ah
500W for 8hContinuous load: 500 W; Operating duration: 8 h370.37037 Ah

Unchanged inputs: Continuous load = 100 W; Operating duration = 8 h; Nominal battery voltage = 12 V; Conversion efficiency = 90 %. Rows change only the listed inputs. Values are arithmetic examples, not manufacturer performance claims.

Common questions

Why do I need the extra input?

This computes consumed Ah. Divide by an additional usable fraction to size a larger battery.

How should I use the result?

This is an algebraic energy or charge calculation. It does not establish a battery discharge rating or charger compatibility.

How do I convert 300 watts to amp hours?

Specify voltage and duration. At 12 V over one hour and 100% efficiency, 300 W requires 25 Ah. At 90% efficiency it requires about 27.78 Ah.

How many amp hours are needed for 100 watts for 8 hours?

At 12 V and 90% efficiency, 100 × 8 / (12 × 0.9) is about 74.07 Ah discharged. Reserving capacity increases the required nameplate Ah.

Can I use this for an RV battery electrical load?

Yes, for one average load or a known combined load over a stated time. For different operating durations, sum each load energy in the home battery load planner first.

What if the load is already measured in DC battery amps?

Use amps times hours directly. Do not apply a second conversion efficiency factor to a battery-side current measurement.

Sources and formula basis

Source addresses are shown as plain text. Algebraic rearrangements, example tables and user-selected loss factors are calculated on this site. A reference does not endorse every illustrative input.

  1. FAA — watt-hour rating: nominal volts × amp-hourshttps://www.faa.gov/hazmat/packsafe/airline-passengers-and-batteries
  2. NIST — SI units and prefixeshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-chapter-4-two-classes-si-units-and-si-prefixes
  3. Cadex Battery University BU-503 — power, energy and timehttps://www.batteryuniversity.com/article/bu-503-determining-power-deliver-by-the-ragone-plot

Source pages checked: November 19, 2026. Verify current product data and locally adopted requirements before design or installation.