Battery Calculatorby Voltage Drop Calculator

Battery calculators / Charging

Understand your battery. Plan your power.

Battery Charger Size Calculator

Find the average charging current needed to replenish a selected capacity in a given time.

Your inputs

Ah
%
%
h
%

Defaults are illustrative. Enter your battery or equipment data. Efficiency and usable capacity inputs are percentages.

Your result

Awaiting your inputs

Enter your values and press Calculate. Your result will appear here.

Explained formula · Sources listed below · No sign-up

The method

Formula and calculation steps

Average charging A = Ah × change in SoC ÷ (hours × coulombic efficiency)

Divide the missing amp-hours by the available time and stored-charge efficiency. The C-rate result lets you compare this average current to a manufacturer current limit.

This is not a charger voltage recommendation. Peak charger current may need to exceed the average due to taper, but must remain within battery limits.

Battery charger capacity and charging-current sizing

Battery charger sizing begins with the charge to restore and the time available. A charger that must support simultaneous DC loads needs additional output beyond the battery charging current computed here. Continuous equipment demand should be added with the correct voltage and measurement boundary.

Compare the calculated average current and C-rate with battery documentation. A charger rated at the computed average may not meet the requested duration if it spends part of the session tapering. Do not increase the current beyond an approved limit simply to force a shorter calculated time.

Worked example

A transparent starting point

100 Ah from 20% to 100% in 8 hours at 95% coulombic efficiency requires 10.53 A average.

The values below are computed with the same formula as the calculator. They are examples, not manufacturer performance claims.

How one input changes the answer

Available charge time (h)Required average charging current
4 h21.05263 A
8 h10.52632 A
12 h7.017544 A

All other inputs use the illustrative defaults in the form.

Battery charger capacity and charging-current sizing — calculated examples

Each row below is calculated from the stated case inputs. Inputs not changed in a row use the assumptions listed after the table.

CaseChanged inputsResult
50Ah recharge in 4hRated battery capacity: 50 Ah; Available charge time: 4 h10.52632 A
50Ah recharge in 8hRated battery capacity: 50 Ah; Available charge time: 8 h5.26316 A
100Ah recharge in 4hRated battery capacity: 100 Ah; Available charge time: 4 h21.05263 A
100Ah recharge in 8hRated battery capacity: 100 Ah; Available charge time: 8 h10.52632 A
150Ah recharge in 4hRated battery capacity: 150 Ah; Available charge time: 4 h31.57895 A
150Ah recharge in 8hRated battery capacity: 150 Ah; Available charge time: 8 h15.78947 A
200Ah recharge in 4hRated battery capacity: 200 Ah; Available charge time: 4 h42.10526 A
200Ah recharge in 8hRated battery capacity: 200 Ah; Available charge time: 8 h21.05263 A

Unchanged inputs: Rated battery capacity = 100 Ah; Starting state of charge = 20 %; Target state of charge = 100 %; Available charge time = 8 h; Coulombic charge efficiency = 95 %. Rows change only the listed inputs. Values are arithmetic examples, not manufacturer performance claims.

Common questions

Can I use any charger with this current?

No. Chemistry, voltage, temperature, BMS and the approved charging algorithm must also match.

How should I use the result?

This is not a charger voltage recommendation. Peak charger current may need to exceed the average due to taper, but must remain within battery limits.

How do I calculate battery charger capacity?

Divide the Ah to restore by the available hours and coulombic efficiency. This yields average battery charging current, before any simultaneous system loads.

How do I choose a charger for a 200Ah battery?

Enter 200 Ah, the starting and target SoC, and the intended charge time. Use the result as an average-current requirement and check the battery permitted charge rate and approved profile.

What is battery charging current as a C-rate?

Divide charging amperes by capacity Ah. A 20 A current into a 100 Ah battery is 0.2 C numerically.

Can this size a DC rectifier or substation charger?

It can estimate replenishment current only. A full design also needs standing load, recovery requirements, redundancy and applicable equipment standards.

Sources and formula basis

Source addresses are shown as plain text. Algebraic rearrangements, example tables and user-selected loss factors are calculated on this site. A reference does not endorse every illustrative input.

  1. Maccor — C-rate in battery testinghttps://www.maccor.com/battery-testing-knowledge-center/fundamentals/understanding-c-rate-in-battery-testing.html
  2. Cadex Battery University BU-903 — state-of-charge measurement methodshttps://www.batteryuniversity.com/article/bu-903-how-to-measure-state-of-charge

Source pages checked: November 19, 2026. Verify current product data and locally adopted requirements before design or installation.